ETEC, Inc. has completed a wide variety of NOx Control projects from large utilitity to small chemical units. The following list contains some of ETEC’s clients, the size and type of boiler and the NOx reduction attained.
|
Company |
Unit Rating and Type |
NOx Reduction
With IFGR* |
|

|
565 MW, Foster Wheeler opposed fired, supercritical |
55% |
|
600 klb/hr, CE T-fired |
57% |
|
600 klb/hr, CE T-fired |
59% |
|
600 klb/hr, CE T-fired |
57% |
|
400 klb/hr, B&W face fired |
53% |
|

|
400 klb/hr, B&W face fired |
53% |
|
600 klb/hr, CE face fired |
73% |
|
250 klb/hr, B&W face fired |
55% |
|
350 klb/hr, B&W face fired |
64% |
|
600 klb/hr, CE face fired |
53% |
|
570 MW, B&W opposed fired, supercritical |
80% |
|
470 MW, B&W opposed fired, supercritical |
58% |
|
565 MW, Foster Wheeler opposed fired, supercritical |
50% |
|

|
290 MW, Foster Wheeler face fired |
70% |
|
565 MW, CE T-fired |
63% |
|
365 MW, Riley Stoker turbo fired |
68% |
|
450 MW, CE T-fired |
65% |
|
220 MW, CE T-fired |
53% |
|
220 MW, CE T-fired |
65% |
|
220 MW, CE T-fired |
65% |
|

|
815 MW, B&W opposed fired, supercritical |
86% |
|
500 MW Foster Wheeler, face fired |
80% |
|

|
351 MW, CE T-fired |
65% |
|

|
18mmbtu Kiln-Maxon Bnr |
80% |
|

|
450 klb/hr CE Face fired |
87% |
|

|
125 MW, Riley Stoker-face fired |
73% |
|

|
120 MW, Riley Stoker-face fired |
88% |
|
125 MW, B&W face fired |
83% |
|

|
150klb/hr, B&W face fired |
55% (Styrene Tar)/NG/LFG |
|
150klb/hr, B&W face fired |
75% (NG+LFG) |
|

|
250 klb/hr, face fired |
55% |
|

|
600 klb/hr, CE T-fired |
73,81,80% |
|
600 klb/hr, CE T-fired |
73% |
|
250 klb/hr, CE face fired |
75% |
|
* Test data results @ guarantee levels. IFGR systems were designed to meet NOx limit specified by the plant. The actual reduction presented in the table does not reflect the maximum reductions that were obtained with IFGR. |
|
** Incorporated Burner System Modifications with IFGR System Operation |
|